dimensions in inches (millimeters) cotomos ? CT140/cs140 te CT140 and cs140 combine coto quality and economy in an industry standard 6 pin dip package. both the CT140 and the cs140 ofer high voltage switching and high load current. te CT140 utilizes a thru hole lead confguration, while the cs140 ofers a surface mount option when the application requires it. both relays are ideally suited to the needs of test and measurement, solar, and battery management. CT140/cs140 features u c ontact form: 1a u l oad voltage: 1500v maximum u o peration led current: 5.0ma maximum u l oad current: 45ma maximum u o n-resistance: 180? typical u l ow of-state leakage current: 10 a maximum u i /o breakdown voltage: 3750vrms minimum u s ufx - h for i/o breakdown voltage: 5000vrms minimum cs140 CT140 CT140/cs140 terminal identification 6 54 1 23 (+) (-) 1: anode (led) 2: cathode (led) 3: nc 4,6: drain (mos fet) 5: source (mos fet) connections 0.047(1.2) 0.252(6.4) 0.358(9.1)max. 0.020(0.5) 0.162(4.1) 0. 11 8( 3.0) identifies pin #1 0.310(7.87)max. 0.376(9.54)max. 0.010(0.25) 0.020(0.5) 0.100(2.54) 0.200(5.08) 0.470(1.2) 0.252(6.4) 0.020(0.5) 0.100(2.54) 0.200(5.08) 0.358(9.1)max. 0.134(3.4) 0.154(3.9)max . 0.051(1.3) 0.010(0.25) 0.406(10.3)max. identifies pin #1 11032015 i f i f i f lo ad v l (a c or dc ) v l (d c) v l (d c) v l (d c) i f co ntrol bi -d irectional signal on-resistance is 1/2 of b-connection on-resistance is 1/2 of a-connection lo ad lo ad lo ad a c b tel: (401) 943.2686 | fax: (401) 942.0920
CT140/cs140 maximum ratings ( ambient temperature: 25oc) parameters symbol units value input specifications continuous led current i f ma 50 peak led current i fp ma 500 led reverse voltage v r v 5 input power dissipation p in mw 75 output specifications load voltage v l v (ac peak or dc) 1500 load current (see connections on previous page) i l ma a 4 5ma (ac or dc) b 5 0ma (dc) c 7 0ma (dc) peak load current i peak ma 200 output power dissipation p out mw 450 relay specifications total power dissipation p t mw 500 i/o breakdown voltage v i/o vrms 3750 operating temperature t opr oc -40 ~ +85 storage temperature t stg oc -40 ~ +100 CT140/cs140 electrical specifications (ambient temperature: 25oc) parameters symbol test conditions units min typ max input led forward voltage v f i f =10ma v 1.0 1.17 1.5 operation led current i f on ma 0.9 5.0 recovery led voltage v f off v 0.5 1.0 output on-resistance drain to drain r on i f =10ma, i l =rating i f =10ma, i l <5ma ? 110 180 200 300 of-state leakage current i leak i f =0ma, v l =1500v a 10 output capacitance c out v l =0v, f=1mhz pf 83 transmission turn-on time t on i f =10ma, i l =rating ms 0.3 1.0 turn-of time t of ms 0.04 0.5 coupled i/o insulation resistance r i/o ? 10 10 i/o capacitance c i/o f=1mhz pf 1.3 environmental ratings: operating temp: -40c to +85c; storage temp: C40 to +100c. 11032015 coto technology, inc. for most recent data visit www.cotorelay.com
40 series graphs 0 1 2 3 4 5 1 2 3 4 5 -40- 20 02 04 06 0 100 85 -40- 20 02 04 06 0 0 0.1 0.2 0.3 0.4 0.5 -40- 20 02 04 06 0 100 85 0 50 100 150 200 250 -40- 20 02 04 06 0 100 85 0 100 85 on resistance vs . ambient temperatur e turn on time vs. ambient temperatur e on resistance, w ambient temperature (oc) ambient temperature (oc) turn on time (ms) ambient temperature (oc) ambient temperature (oc) ambient temperature (oc) turn off time vs. ambient temperatur e led operate current vs . ambient temperatur e led turn off current vs. ambient temperatur e turn off time (ms) led operate current (ma) led turn off current (ma) led forward voltage vs . ambient temperatur e ambient temperature (oc) led dropout voltage (v) -40- 20 02 04 06 08 5 100 0 20 40 50 60 ambient temperature (oc) load current vs . ambient temperatur e load current (ma) 30 10 0 0.5 1.0 1.5 2.5 2.0 3.0 -40- 20 02 04 06 0 100 85 0 1.5 -40- 20 02 04 06 0 100 85 1.1 1.0 1.2 1.3 1.4 0 5 10 15 20 25 -5 1 -10 -15 -20 -25 2345 -5 -4 -3 -2 -1 vo ltage,v current,ma voltage vs. current characteristics of output at mos portion off state leakage current 0 200 400 600 800 1000 10 -12 10 -9 10 -6 10 -3 1200 1400 1600 off state leakage current (a) load voltage (v ) 01 02 03 04 06 0 0 0.2 50 0.4 0.6 0.8 1.0 1.2 led foward current vs . turn on time characteristic s turn on time (ms) led foward current (ma) 0 0.02 01 02 03 04 05 0 0.04 0.06 0.08 0.10 0.12 60 led foward current vs . turn off time characteristic s turn off time (ms) led foward current (ma) 01 02 03 04 05 0 0 100 200 50 150 applied voltage vs. output capacitance characteristics output capacitance (pf) applied voltage (v) 11032015 tel: (401) 943.2686 | cotorelay.com coto technology, inc.
|